Conductor material: bare copper wire
Conductor grade: acc. to IEC 60228 cl. 5standard
Insulation:PVC-J-105-003(2105-LF)
Identification of core wire:< 0,5 mm²:5Core and below the use of color separation, in line withn. DIN 47100.5Multi-core cable above core adopts core separation , white ink dot distinguish; ≥ 0,5 mm²: 5Core and below use color separation, containing
yellow/Green line, matchn. DIN 47100.5Multi-core cable above the core adopts black core wire, white ink numbered to distinguish(If there are special requirements to customize)
Stranding: Stranded in layers
Outer sheath:TPU-H-90-004Flame retardant
Jacket color: Black RAL9005;grey RAL 7001
Rated voltage:0.5 And below 300/300V;0.5 above 300/500V
Test voltage:0.5 And below 1500V;0.5 above 2000V
Conductor resistance: acc. to IEC 60228 cl. 5standard
Insulation resistance: minimum 20 MΩ x km
Capacitance: ca. 120 nF/km
Min. bending radius fixed:12mm The following Ø 5 x d; 20mmThe following Ø 7,5 x d; > 20mm Ø 10 x d
Min. bending radius moved:12mm The followingØ 10 x d; 20mmThe followingØ 15 x d; > 20mm Ø 20 x d
Operat. temp. fixed min/max:-40 °C / +80 °C
Operat. temp. moved min/max:-30 °C / +80 °C
Burning behavior:Self-extinguishing and flame retardant meet IEC 60332-1-2standard
Standard:DIN VDE 0812
Product identification:Aein bei ke SHANGHAI AEIN WIRE & CABLE CO.,LTD Model number specification voltage CE Meter scale