Product introduction
-
01 Product application Used for fixed laying on rolling stock and buses, as well as dry indoor, pipe and closed aqueducts. Suitable for connecting flexible units.
-
02 Product characteristics • Operating voltage is 3kV Cable in 1kV The following low voltage facilities are listed as short circuit and leakage protection connections.
• Flame retardant coincidence IEC 60332-1-2 • Conform to EN 60811-404 Oil resistance of
-
03 Technical certification • Conform to RoHS• We are pleased to produce special versions, other dimensions, core and jacket colours on request.
Structural parameter
Conductor material: Tinned copper stranded wire
Conductor class: In accordance with DIN VDE 0295 5 Class, refer to IEC 60228 5 class
Core insulation:3GI3 Type b rubber mixture
Outer sheathing material:5GM3 Type rubber mixture
Color of outer sheath:Black
Rated voltage:1.8/3 kV
Test voltage:6 kV
Min. bending radius fixed:5 XD
Min. bending radius moved:5 XD
Operat. temp. fixed min/max: -40 °C / +90 °C
Operat. temp. moved min/max:-30 °C / +90 °C
Flame retardant:IEC60332-1-2
Standard:Conform to DIN VDE 0250-602
Product identification Aein bei ke SHANGHAI AEIN WIRE & CABLE CO.,LTD Model number specification voltage CE Meter scale
Product parameter