Product introduction
-
01 Product application
Power supply cable for use in water, e.g. for connection to dredgers, floating docks, pumps, etc., in applications where high mechanical stresses are to be expected. Also suitable for use in sewage, salt water and brackish water at water depths of up
to 500 m. This screened cable design is suitable for the use with dredging equipment.
-
02 Product characteristics
Rated voltage: 3.6/6 kV
Max. permissible operating voltage AC: 4.2/7.2 kV
Max. permissible operating voltage DC: 5.4/10.8 kV
AC test voltage: 11 kV
AC test voltage - main cores: 11 kV ( Min.)
Max. tensile load on the conductor: 15 N/mm²
Torsional stress: +/- 25 °/m
-
03 Technical certification ·RoHS Compliant
·Complies with 2014/35/EU-Guidelines ("Low Voltage Directive") CE.
• We are pleased to produce special versions, other dimensions, core and jacket colours on request.
Product structure
Conductor: Electrolytic copper, tinned, finely stranded (class 5)
Insulation: Basic material EPR, Compound type: 3GI3
Electrical field control: Inner and outer layer of semiconductive rubber compound and metallic concentric screen on each core
Core identification: Natural coloring with black semiconductive rubber
Core arrangement: Three main conductor laid-up with individual concentric protective-earth conductors distributed over the insulation of the three main cores
Inner sheath: EPR inner sheath with special characteristics with respect to water proofing and prevention of formation of water bubbles, Compound type: GM1B
Outer sheath: Basic material: synthetic elastomer compound e.g. CM (particularly water-proof), Compound type: 5GM3, Color: Red