hot keywords:

RE-Y(St)Y-fI TIMF Cable

RE-Y(St)Y-fI TIMF Cable

These cables used for connecting instruments and control systems for analogue or digital signal transmission for indoor and outdoor applications.These cables shall not be connected directly to mains electricity supply or other low impedance sources, since they are not designed to be used for power supply.

Certification :   European CE certification  

Voltage :   500V     300/500V     1000V  

Low temperature :   —5°C  

High temperature :   70°C  

Insulation material :   PVC  

Sheath material :   PVC  

Shielding :   Shield  

Installation way :   Occasional flexing     Fixed installation  

Environment :   General indoor environment     General outdoor environment     Corrosive environment  

inquiry
  • Product details
Product introduction
  • 01 Product application



    These cables used for connecting instruments and control systems for analogue or digital signal transmission for indoor and outdoor applications.These cables shall not be connected directly to mains electricity supply or other low impedance sources, since they are not designed to be used for power supply.




  • 02 Product characteristics



    Hydrocarbon resistant

    Oil resistant

    Anti termit / anti rodent

    UV resistant

    LSF (Low Smoke) version


    Flame retardant

  • 03 Technical certification ·RoHS Compliant
    ·Complies with 2014/35/EU-Guidelines ("Low Voltage Directive") CE.
    We are pleased to produce special versions, other dimensions, core and jacket colours on request.
Product structure


CONDUCTOR :Electrolytic, stranded, annealed plain copper wires to IEC 60228 Class 2 (Class 1 or Class 5 and / or tinned on request)

INSULATION :PVC compound to EN50290-2-21 Black / White / Red twisted triads with numbered cores

BINDER TAPE :Polyester foil on each twisted triad

INDIVIDUAL SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil

BINDER TAPE :Polyester foil on overall cable core formed by stranded triples

COLLECTIVE SCREEN :Aluminum/polyester foil with a tinned copper drain wire in direct contact with the metallic side of the foil

OUTER SHEATH :Flame retardant PVC compound to EN50290-2-22 

RATED VOLTAGE :500 V a.c.

AC TEST VOLTAGE :2000 V x 1 min. (core:core / core: screen)

WORKING TEMPERATURE : -30°C / + 70°C (during operation) – 5 °C / + 50°C (during installation)

MIN BENDING RADIUS (FIXED) :7,5 x D