For hotels, schools, tunnels, high-rise buildings, hospitals, power plants, data processing, commercial and other energy networks with fire risks. These cables with low dielectric loss and mechanical resistance are mainly used in residential or industrial energy networks with sudden changes in load. It can be laid outdoors, underground and in areas where sudden mechanical stress is expected.


inquiry
  • Product details
Product introduction
  • 01 Product application

    Used in hotels, schools, tunnels, high-rise buildings, hospitals, power plants, data processing, business and other fire wind, risk of energy networks. These cables with low dielectric loss and mechanical resistance are mainly used in residential or industrial energy networks with sudden changes in load. It can be laid outdoors, underground and in areas where sudden mechanical stress is expected.

  • 02 Product characteristics

    Flame retardant in accordance with IEC 60332-1-2
    Non-delay performance in accordance with IEC 60332-3-24
    Halogen-free according to IEC 60754-1:2011(Total halogen acid gas)
    Combustion gas corrosivity in accordance with IEC 60754-2:2011(acidity)
    Low smoke density in accordance with IEC 61034-2:2005+A12013+A2:2020

  • 03 Technical certification

    · Comply with RoHS standards
    · Compliance with 2014/35/EU- Guideline ("Low Voltage Directive ")CE

Product structure

Conductor material: bare copper wire

Conductor class: According to IEC 60228 c.5 standard cI.2 Optional

Insulation :XLPE

Core identifier: Black core with white number, GNYE without through

Stranding: stranding in layers

Outer sheath: halogen-free, thermoplastic polyolefin mixture

Jacket color: black, RAL9005 or grey RAL7001

Rated voltage :0.6/1 kV

Test voltage :3.5 kV

Conductor resistance: According to IEC 60228 cI.5

The rated temperature of the conductor is 90°C

When short-circuiting (5s or less) occurs, the conductor temperature does not exceed 250°C

Small bending radius constant :7.5 x d

Small bending radius movement :15 x d

Fixed temperature rating :-25°C/+90°C

Temperature rating shift :-25°C/+90°C

Flame retardant rating :IEC 60332-1-2

Standard :HD 603-3G IEC60502-1

Product identification: Aein bei ke SHANGHAI AEIN WIRE & CABLE CO.. LTD Model Specification Voltage CE meter standard

Keywords: RZ1MZ1-K(AS) cable

Recommended news