Conductor material: bare copper wire
Conductor class: According to DIN VDE 0295 Class 6 conductor or IEC 60228 Class 6 conductor
Insulation :PVC-J-105-003(2105-LF)(PP/HDPE optional)
Core identifier :< 0.5mm ²; 5 core and below using color separation, in line with n.DIN 47100, more than 5 core multi-core cable using core wire color separation, white ink dot distinction; ≥0.5mm²; Color separation is used for 5-core and below, including
yellow/green wire, in line with n.DIN 47100, multi-core cables with more than 5-core black core wire, white ink numbered distinction (customized according to special requirements)
Cabling: core twisted pair or layer twisted, more detailed structure, please refer to the product technical parameters
Shielding layer: tinned copper wire braid shielding shielding density ≥80%
Outer sheath: PUR flame retardant
Jacket color: black (RAL 9005): Grey (RAL 7001): Green (RAL 6018)
Rated voltage :30V; 300V
Test voltage :500V, 1500V
Small bending radius: fixed 4 x d
Small bending radius: Move 7.5 x d
Moving speed: Self-supporting: max.8 m/s, coasting: max.5 m/s
Conductor length: Self-supporting/coasting max.400 m
Acceleration :max.100 m/s²
Bending cycle :<35 times /Min, life >12 million times
Temperature rating is fixed :-50°C/+80°C
Temperature rating shift :-40°C/+80C
Smoldering grade: According to IEC 60332-1-2,cable flame test, FT1, FT2
Certification :CE; UL/CUL If UL certification and halogen-free requirements are required, please note them separately