UL& CUL certified data transmission cables, control and connection cables are mainly used to transmit analog and digital signals in the process control facilities of measurement and control technology, to achieve lossless data and signal transmission, suitable for high demand towed chains and mobile drive systems. External connection cables for electronic devices. With oil resistance, abrasion resistance, acid and alkali resistance, waterproof, UV resistance.
inquiry
  • Product details
Product introduction
  • 01 Product applicationUL&CULCertified data transmission cables, control and connection cables are used to transmit analog and digital signals in process control facilities of measurement and control technology, enabling lossless data and signal transmission for use in highly demanding towing chains and mobile drive systems. External connection cables for electronic devices. With oil resistance, abrasion resistance, acid and alkali resistance, waterproof, anti UV Features.
  • 02 Product characteristics • Conform to RoHS
    • UV resistance
    • Flame retardant in accordance with CSA C22.2 No.2556-15 FT2
    • Oil resistance Conform to UL1581:IRM 902. DIN EN 60811-1-2
    • Recommend for EMC Compatible application
    • Strong tolerance to oils, coolants and lubricants
  • 03 Technical certification • Conform to UL&CUL Standard,UL758, CSA C22.2 No. 210
    • Conform to 2014/35/EU-Guideline (''Low voltage Directive'') CE
    • We are pleased to produce special versions, other dimensions, core and jacket colours on request.
Product structure

Conductor material: Bare copper or tinned copper

Conductor type: In accordance with UL758 Standard, ASTM B3 or ASTM B33 Standard, DIN VDE 0295 5 Conductor or. IEC 60228 5 Conductor

Core insulation:PVC,HDPE,TPE optional

Core identification:<20AWG: 5 cores and below are distinguished by color separation, acc. to Din 47100, multi-core cables above 5 cores are distinguished by core wire color separation, and white ink is used for distinction; ≥20AWG: 5 cores and below are distinguished by color separation, including yellow/ Green ground wire, acc.to Din 47100, multi-core cables with more than 5 cores use black core wires, and white ink numbers are used to distinguish them. (customized upon request if there are special requirements)

Stranding:The core wires are stranded in layers or of parallel structure, and the parallel structure does not exceed 3 Line group

Sheath: Flame retardant TPU

Jacket color: Gray RAL7001 Or black RAL9005

Rated voltage: In accordance with UL:300V; Conform to CE:300/300V

Test voltage:Core/Core: 2.0kV

Conductor resistance:UL1581 ASTM C class

Insulation resistance:PVC:+20 °C ≥ 20 MΩ x km;HDPE:+20 °C ≥ 500 MΩ x km

Min. bending radius fixed:4x d

Min. bending radius moved:7.5x d

Velocity of movement Self-supporting:max. 10 m/s, glide: max. 5 m/s

Conductor length:max. 50 m

acceleration:max. 20 m/s²

Bending cycle:<35 time/Min; Life span>1200 Ten thousand times

Operat. temp. fixed min/max HDPE:-50 °C / +80 °C 

Operat. temp. moved min/max HDPE:-40 °C / +80 °C

Burning behavior: Self-extinguishing and flame retardant FT2

Oil resistance:UL1581:IRM 902; Conform to DIN EN 60811-2-1

Approvals: UL&CUL:UL11470,UL20233
           CE:Li2Y11Y  If needed CE Certification requirements should be specified separately