Conductor material: Bare copper or tinned copper
Conductor type: In accordance with UL758 Standard, ASTM B3 or ASTM B33 Standard, DIN VDE 0295 5 Conductor or. IEC 60228 5 Conductor
Core insulation:PVC,HDPE,TPE optional
Core identification:<20AWG: 5 cores and below are distinguished by color separation, acc. to Din 47100, multi-core cables above 5 cores are distinguished by core wire color separation, and white ink is used for distinction; ≥20AWG: 5 cores and below are distinguished by color separation, including yellow/ Green ground wire, acc.to Din 47100, multi-core cables with more than 5 cores use black core wires, and white ink numbers are used to distinguish them. (customized upon request if there are special requirements)
Strandling:Layered or parallel structure of cores
shield:Tinned copper braid, shielding density 70 %
Sheath: Flame retardant TPU
Jacket color: Gray RAL7001 Or black RAL9005
Rated voltage: In accordance with UL:300V; Conform to CE:300/300V
Test voltage:Core wire/Core wire: 2.0kV
Conductor resistance:UL1581 ASTM C class
Insulation resistance:PVC:+20 °C ≥ 20 MΩ x km;HDPE:+20 °C ≥ 500 MΩ x km
Min. bending radius fixed:4x d
Min. bending radius moved:7.5x d
Velocity of movement:Self-supporting:max. 10 m/s, glide: max. 5 m/s
Conductor length:max. 50 m
acceleration:max. 20 m/s²
Bending cycle:<35 time/Min; Life span>1200Ten thousand times
Operat. temp. fixed min/max HDPE&TPE:-50 °C / +80 °C ; PVC:-40 °C / +80 °C
Operat. temp. moved min/max HDPE&TPE:-40 °C / +80 °C ; PVC-30 °C / +80 °C
Burning behavior: Self-extinguishing and flame retardant;CSA C22.2 No.2556-15 FT2
Oil resistance:UL1581:IRM 902; Conform to DIN EN 60811-2-1
Approvals:UL&CUL:UL1007,UL1185,UL1569,UL11076,UL10450,UL10586,UL10149,UL20549
CE:LiYC11Y,Li2YC11Y,Li12YC11Y If needed CE Certification or halogen-free requirements shall be indicated separately
Product identification:Aein bei ke E503807 ® AWM Model number specification temperature voltage ® AWM Ⅰ/Ⅱ A/B specification temperature voltage FT2 SHANGHAI AEIN Meter scale