Conductor: DIN VDE 0295 standard class 5 soft stranded tinned copper conductor.
Conductor resistance: Comply with UL758 standard, ASTM B3 or ASTM B33 standard. vde 0295 class 5 conductor pt.4 or iec 60228 class 5 conductor pt.4.
Insulation PVC, XLPE and TPE are optional.
Core identification: According to DIN VDE 0293, black with white number, 1 x GNYE.
Rated voltage: Uo/U: 600 V/1000 V
Sheath: PVC
Jacket color: Gray RAL7001 Or black RAL9005
Test voltage: 3000V
Conductor resistance:UL1581 ASTM class C
Insulation resistance:+20 °C ≥ 20 MΩ x km
Minimum fixed bending radius: 10 x d
Minimum flexible bending radius: 4 x d
Working Temperature: 80°C
Burning behaviour: Self-extinguishing and flame retardant UL1581 VW-1;CSA C22.2 No.2556-15 FT1,FT2;IEC 60332-1-2 standard
Standard: UL&CULUL1015, UL10914, UL11122, UL3271, UL3321, UL3386, UL3196, UL3289, UL3237, UL3820, UL2586
CE: YSLCY、2XSLCY If needed CE Certification requirements should be specified separately
Marking: Aein bei ke E503807 ® AWM Model number specification temperature voltage ® AWM Ⅰ/Ⅱ A/B specification temperature voltage FT2 SHANGHAI AEIN Meter scale